ICD-10-PCS › 0 Medical and Surgical › 05 Upper Veins › 05H Upper Veins, Insertion › 05HL03Z
Insertion of Infusion Device into Intracranial Vein, Open Approach
ValidICD-10-PCS procedure code.
Valid for claims with a date of service in the current code year.
What has happened to this code
Every change the publisher made, from 2014 to now. Entries marked draft are from the pre-implementation releases: ICD-10 took effect on 1 October 2015, so nothing before FY2016 was ever valid on a claim.
- FY2014 Added to the draft code set draft Insertion of Infusion Device into Intracranial Vein, Open Approach
What this code says
Each character is read in its own position, so the same letter means different things in different places. Definitions are CMS's own.
3. Root operation Insertion
Putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part
For example
- Insertion of radioactive implant, insertion of central venous catheter
4. Body Part Intracranial Vein
Also covers
- Anterior cerebral vein
- Basal (internal) cerebral vein
- Dural venous sinus
- Great cerebral vein
- Inferior cerebellar vein
- Inferior cerebral vein
- Internal (basal) cerebral vein
- Middle cerebral vein
5. Approach Open
Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure
6. Device Infusion Device
For example
- Ascenda Intrathecal Catheter
- InDura, intrathecal catheter (1P) (spinal)
- Non-tunneled central venous catheter
- Peripherally inserted central catheter (PICC)
- Tunneled spinal (intrathecal) catheter
Codes in the same group
| Code | Description | Status |
|---|---|---|
| 05H002Z | Insertion of Monitoring Device into Azygos Vein, Open Approach | Valid |
| 05H003Z | Insertion of Infusion Device into Azygos Vein, Open Approach | Valid |
| 05H00DZ | Insertion of Intraluminal Device into Azygos Vein, Open Approach | Valid |
| 05H00MZ | Insertion of Neurostimulator Lead into Azygos Vein, Open Approach | Valid |
| 05H032Z | Insertion of Monitoring Device into Azygos Vein, Percutaneous Approach | Valid |
| 05H033Z | Insertion of Infusion Device into Azygos Vein, Percutaneous Approach | Valid |
| 05H03DZ | Insertion of Intraluminal Device into Azygos Vein, Percutaneous Approach | Valid |
| 05H03MZ | Insertion of Neurostimulator Lead into Azygos Vein, Percutaneous Approach | Valid |
| 05H042Z | Insertion of Monitoring Device into Azygos Vein, Percutaneous Endoscopic Approach | Valid |
| 05H043Z | Insertion of Infusion Device into Azygos Vein, Percutaneous Endoscopic Approach | Valid |
| 05H04DZ | Insertion of Intraluminal Device into Azygos Vein, Percutaneous Endoscopic Approach | Valid |
| 05H04MZ | Insertion of Neurostimulator Lead into Azygos Vein, Percutaneous Endoscopic Approach | Valid |