ICD-10-PCS › 0 Medical and Surgical › 05 Upper Veins › 05H Upper Veins, Insertion › 05HA4DZ

05HA4DZ

Insertion of Intraluminal Device into Left Brachial Vein, Percutaneous Endoscopic Approach

ValidICD-10-PCS procedure code.

Valid for claims with a date of service in the current code year.

Valid FY2016 onwards.

What has happened to this code

Every change the publisher made, from 2014 to now. Entries marked draft are from the pre-implementation releases: ICD-10 took effect on 1 October 2015, so nothing before FY2016 was ever valid on a claim.

  1. FY2014 Added to the draft code set draft Insertion of Intraluminal Device into Left Brachial Vein, Percutaneous Endoscopic Approach

What this code says

Each character is read in its own position, so the same letter means different things in different places. Definitions are CMS's own.

3. Root operation Insertion

Putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part

For example

  • Insertion of radioactive implant, insertion of central venous catheter

4. Body Part Brachial Vein, Left

Also covers

  • Radial vein
  • Ulnar vein

5. Approach Percutaneous Endoscopic

Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach and visualize the site of the procedure

6. Device Intraluminal Device

For example

  • Absolute Pro Vascular (OTW) Self-Expanding Stent System
  • Acculink (RX) Carotid Stent System
  • AFX(R) Endovascular AAA System
  • AneuRx(R) AAA Advantage(R)
  • Assurant (Cobalt) stent
  • Carotid WALLSTENT(R) Monorail(R) Endoprosthesis
  • CoAxia NeuroFlo catheter
  • Colonic Z-Stent(R)

Codes in the same group

CodeDescriptionStatus
05H002Z Insertion of Monitoring Device into Azygos Vein, Open Approach Valid
05H003Z Insertion of Infusion Device into Azygos Vein, Open Approach Valid
05H00DZ Insertion of Intraluminal Device into Azygos Vein, Open Approach Valid
05H00MZ Insertion of Neurostimulator Lead into Azygos Vein, Open Approach Valid
05H032Z Insertion of Monitoring Device into Azygos Vein, Percutaneous Approach Valid
05H033Z Insertion of Infusion Device into Azygos Vein, Percutaneous Approach Valid
05H03DZ Insertion of Intraluminal Device into Azygos Vein, Percutaneous Approach Valid
05H03MZ Insertion of Neurostimulator Lead into Azygos Vein, Percutaneous Approach Valid
05H042Z Insertion of Monitoring Device into Azygos Vein, Percutaneous Endoscopic Approach Valid
05H043Z Insertion of Infusion Device into Azygos Vein, Percutaneous Endoscopic Approach Valid
05H04DZ Insertion of Intraluminal Device into Azygos Vein, Percutaneous Endoscopic Approach Valid
05H04MZ Insertion of Neurostimulator Lead into Azygos Vein, Percutaneous Endoscopic Approach Valid