ICD-10-PCS › 0 Medical and Surgical › 04 Lower Arteries › 04V Lower Arteries, Restriction › 04VD3FZ
04VD3FZ
Restriction of Left Common Iliac Artery with Branched or Fenestrated Intraluminal Device, Three or More Arteries, Percutaneous Approach
RetiredICD-10-PCS procedure code.
No longer in the code set. Submitting it will not be accepted for a current date of service.
Use instead:
- 04VD3DZ Restriction of Left Common Iliac Artery with Intraluminal Device, Percutaneous Approach stated for FY2017
What has happened to this code
Every change the publisher made, from 2017 to now.
- FY2017 Added to the code set Restriction of Left Common Iliac Artery with Branched or Fenestrated Intraluminal Device, Three or More Arteries, Percutaneous Approach
- FY2018 Removed from the code set
What this code says
Each character is read in its own position, so the same letter means different things in different places. Definitions are CMS's own.
3. Root operation Restriction
Partially closing an orifice or the lumen of a tubular body part
The orifice can be a natural orifice or an artificially created orifice
For example
- Esophagogastric fundoplication, cervical cerclage
5. Approach Percutaneous
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure
Codes in the same group
| Code | Description | Status |
|---|---|---|
| 04V00C6 | Restriction of Abdominal Aorta, Bifurcation, with Extraluminal Device, Open Approach | Retired |
| 04V00CZ | Restriction of Abdominal Aorta with Extraluminal Device, Open Approach | Valid |
| 04V00D6 | Restriction of Abdominal Aorta, Bifurcation, with Intraluminal Device, Open Approach | Retired |
| 04V00DJ | Restriction of Abdominal Aorta with Intraluminal Device, Temporary, Open Approach | Valid |
| 04V00DZ | Restriction of Abdominal Aorta with Intraluminal Device, Open Approach | Valid |
| 04V00E6 | Restriction of Abdominal Aorta, Bifurcation, with Branched or Fenestrated Intraluminal Device, One or Two Arteries, Open Approach | Retired |
| 04V00EZ | Restriction of Abdominal Aorta with Branched or Fenestrated Intraluminal Device, One or Two Arteries, Open Approach | Valid |
| 04V00F6 | Restriction of Abdominal Aorta, Bifurcation, with Branched or Fenestrated Intraluminal Device, Three or More Arteries, Open Approach | Retired |
| 04V00FZ | Restriction of Abdominal Aorta with Branched or Fenestrated Intraluminal Device, Three or More Arteries, Open Approach | Valid |
| 04V00Z6 | Restriction of Abdominal Aorta, Bifurcation, Open Approach | Retired |
| 04V00ZZ | Restriction of Abdominal Aorta, Open Approach | Valid |
| 04V03C6 | Restriction of Abdominal Aorta, Bifurcation, with Extraluminal Device, Percutaneous Approach | Retired |