ICD-10-PCS › 0 Medical and Surgical › 02 Heart and Great Vessels › 024 Heart and Great Vessels, Creation › 024J0J2

024J0J2

Creation of Tricuspid Valve from Common Atrioventricular Valve using Synthetic Substitute, Open Approach

ValidICD-10-PCS procedure code.

Valid for claims with a date of service in the current code year.

Valid FY2017 onwards.

What has happened to this code

Every change the publisher made, from 2017 to now.

  1. FY2017 Added to the code set Creation of Tricuspid Valve from Common Atrioventricular Valve using Synthetic Substitute, Open Approach

What this code says

Each character is read in its own position, so the same letter means different things in different places. Definitions are CMS's own.

3. Root operation Creation

Putting in or on biological or synthetic material to form a new body part that to the extent possible replicates the anatomic structure or function of an absent body part

Used for gender reassignment surgery and corrective procedures in individuals with congenital anomalies

For example

  • Creation of vagina in a male, creation of right and left atrioventricular valve from common atrioventricular valve

4. Body Part Tricuspid Valve

Also covers

  • Right atrioventricular valve
  • Tricuspid annulus

5. Approach Open

Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure

6. Device Synthetic Substitute

For example

  • AbioCor(R) Total Replacement Heart
  • AMPLATZER(R) Muscular VSD Occluder
  • Annuloplasty ring
  • Bard(R) Composix(R) (E/X)(LP) mesh
  • Bard(R) Composix(R) Kugel(R) patch
  • Bard(R) Dulex(tm) mesh
  • Bard(R) Ventralex(tm) hernia patch
  • Barricaid(R) Annular Closure Device (ACD)

Codes in the same group

CodeDescriptionStatus
024F07J Creation of Aortic Valve from Truncal Valve using Autologous Tissue Substitute, Open Approach Valid
024F08J Creation of Aortic Valve from Truncal Valve using Zooplastic Tissue, Open Approach Valid
024F0JJ Creation of Aortic Valve from Truncal Valve using Synthetic Substitute, Open Approach Valid
024F0KJ Creation of Aortic Valve from Truncal Valve using Nonautologous Tissue Substitute, Open Approach Valid
024G072 Creation of Mitral Valve from Common Atrioventricular Valve using Autologous Tissue Substitute, Open Approach Valid
024G082 Creation of Mitral Valve from Common Atrioventricular Valve using Zooplastic Tissue, Open Approach Valid
024G0J2 Creation of Mitral Valve from Common Atrioventricular Valve using Synthetic Substitute, Open Approach Valid
024G0K2 Creation of Mitral Valve from Common Atrioventricular Valve using Nonautologous Tissue Substitute, Open Approach Valid
024J072 Creation of Tricuspid Valve from Common Atrioventricular Valve using Autologous Tissue Substitute, Open Approach Valid
024J082 Creation of Tricuspid Valve from Common Atrioventricular Valve using Zooplastic Tissue, Open Approach Valid
024J0K2 Creation of Tricuspid Valve from Common Atrioventricular Valve using Nonautologous Tissue Substitute, Open Approach Valid