Each character is read in its own position, so the same letter means different things in different places. Definitions are CMS's own.
3. Root operation Insertion
Putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part
For example
- Insertion of radioactive implant, insertion of central venous catheter
4. Body Part Cerebral Ventricle
Also covers
- Aqueduct of Sylvius
- Cerebral aqueduct (Sylvius)
- Choroid plexus
- Ependyma
- Foramen of Monro (intraventricular)
- Fourth ventricle
- Interventricular foramen (Monro)
- Left lateral ventricle
5. Approach Percutaneous
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure
6. Device Infusion Device
For example
- Ascenda Intrathecal Catheter
- InDura, intrathecal catheter (1P) (spinal)
- Non-tunneled central venous catheter
- Peripherally inserted central catheter (PICC)
- Tunneled spinal (intrathecal) catheter
Codes in the same group
| Code | Description | Status |
|---|---|---|
| 00H001Z | Insertion of Radioactive Element into Brain, Open Approach | Valid |
| 00H002Z | Insertion of Monitoring Device into Brain, Open Approach | Valid |
| 00H003Z | Insertion of Infusion Device into Brain, Open Approach | Valid |
| 00H004Z | Insertion of Radioactive Element, Cesium-131 Collagen Implant into Brain, Open Approach | Valid |
| 00H005Z | Insertion of Radioactive Element, Palladium-103 Collagen Implant into Brain, Open Approach | Valid |
| 00H00MZ | Insertion of Neurostimulator Lead into Brain, Open Approach | Valid |
| 00H00YZ | Insertion of Other Device into Brain, Open Approach | Valid |
| 00H031Z | Insertion of Radioactive Element into Brain, Percutaneous Approach | Valid |
| 00H032Z | Insertion of Monitoring Device into Brain, Percutaneous Approach | Valid |
| 00H033J | Insertion of Infusion Device into Brain, Temporary, Percutaneous Approach | Valid |
| 00H033Z | Insertion of Infusion Device into Brain, Percutaneous Approach | Valid |
| 00H03MZ | Insertion of Neurostimulator Lead into Brain, Percutaneous Approach | Valid |