ICD-10-CM › S00-T88 › T80-T88 › T85.120 Displacement of implanted... › T85.120S
Displacement of implanted electronic neurostimulator of brain electrode (lead), sequela
ValidICD-10-CM diagnosis code.
Valid for claims with a date of service in the current code year.
What has happened to this code
Every change the publisher made, from 2007 to now. Entries marked draft are from the pre-implementation releases: ICD-10 took effect on 1 October 2015, so nothing before FY2016 was ever valid on a claim.
- FY2007 Added to the draft code set draft Displacement of implanted electronic neurostimulator (electrode) of brain, sequela
-
FY2017
Description revised
Displacement of implanted electronic neurostimulator (electrode) of brain, sequelaDisplacement of implanted electronic neurostimulator of brain electrode (lead), sequela
Official coding rules
Published by CDC for FY2027. A rule attached to a category binds every code beneath it, so the rules inherited from this code's ancestors are shown with the code they come from.
Inherited from T85 Complications of other internal prosthetic devices, implants and grafts
Seventh character required
- The appropriate 7th character is to be added to each code from category T85
Excludes2 - not included here
- failure and rejection of transplanted organs and tissue (T86.-)
Inherited from the T80-T88 section Complications of surgical and medical care, not elsewhere classified (T80-T88)
Excludes2 - not included here
- any encounters with medical care for postprocedural conditions in which no complications are present, such as:
- artificial opening status (Z93.-)
- closure of external stoma (Z43.-)
- fitting and adjustment of external prosthetic device (Z44.-)
- burns and corrosions from local applications and irradiation (T20-T32)
- complications of surgical procedures during pregnancy, childbirth and the puerperium (O00-O9A)
- mechanical complication of respirator [ventilator] (J95.850)
- poisoning and toxic effects of drugs and chemicals (T36-T65 with fifth or sixth character 1-4 or 6)
- postprocedural fever (R50.82)
- specified complications classified elsewhere, such as:
- cerebrospinal fluid leak from spinal puncture (G97.0)
- colostomy malfunction (K94.0-)
- disorders of fluid and electrolyte imbalance (E86-E87)
- functional disturbances following cardiac surgery (I97.0-I97.1)
- intraoperative and postprocedural complications of specified body systems (D78.-, E36.-, E89.-, G97.3-, G97.4, H59.3-, H59.-, H95.2-, H95.3, I97.4-, I97.5, J95.6-, J95.7, K91.6-, L76.-, M96.-, N99.-)
- ostomy complications (J95.0-, K94.-, N99.5-)
- postgastric surgery syndromes (K91.1)
- postlaminectomy syndrome NEC (M96.1)
- postmastectomy lymphedema syndrome (I97.2)
- postsurgical blind-loop syndrome (K91.2)
- ventilator associated pneumonia (J95.851)
Use additional code
- code for adverse effect, if applicable, to identify drug (T36-T50 with fifth or sixth character 5)
- code(s) to identify the specified condition resulting from the complication
- code to identify devices involved and details of circumstances (Y62-Y82)
How CDC's index refers to this code
Wording from the official alphabetic index. Much of it appears nowhere in the code description, which is why a search for the everyday phrase so often finds nothing.
- Complication > brain neurostimulator
- Complication > electronic stimulator device > nervous system > brain
- Complication > electronic stimulator device > brain > mechanical > malposition
- Complication > electronic stimulator device > brain > mechanical > displacement
Codes in the same group
| Code | Description | Status |
|---|---|---|
| T85.120A | Displacement of implanted electronic neurostimulator of brain electrode (lead), initial encounter | Valid |
| T85.120D | Displacement of implanted electronic neurostimulator of brain electrode (lead), subsequent encounter | Valid |