ICD-10-CM › S00-T88 › T80-T88 › T82.12 Displacement of cardiac electronic device › T82.129
Displacement of unspecified cardiac electronic device
Not billableICD-10-CM diagnosis code.
This code exists but cannot be submitted on its own. It groups the more specific codes beneath it.
Submit one of these 3 more specific codes instead:
- T82.129A Displacement of unspecified cardiac electronic device, initial encounter
- T82.129D Displacement of unspecified cardiac electronic device, subsequent encounter
- T82.129S Displacement of unspecified cardiac electronic device, sequela
This code requires a seventh character. See the rule below.
What has happened to this code
Every change the publisher made, from 2014 to now. Entries marked draft are from the pre-implementation releases: ICD-10 took effect on 1 October 2015, so nothing before FY2016 was ever valid on a claim.
- FY2014 Added to the draft code set draft Displacement of unspecified cardiac electronic device
Official coding rules
Published by CDC for FY2027. A rule attached to a category binds every code beneath it, so the rules inherited from this code's ancestors are shown with the code they come from.
Inherited from T82 Complications of cardiac and vascular prosthetic devices, implants and grafts
Seventh character required
- The appropriate 7th character is to be added to each code from category T82
Excludes2 - not included here
- failure and rejection of transplanted organs and tissue (T86.-)
Inherited from the T80-T88 section Complications of surgical and medical care, not elsewhere classified (T80-T88)
Excludes2 - not included here
- any encounters with medical care for postprocedural conditions in which no complications are present, such as:
- artificial opening status (Z93.-)
- closure of external stoma (Z43.-)
- fitting and adjustment of external prosthetic device (Z44.-)
- burns and corrosions from local applications and irradiation (T20-T32)
- complications of surgical procedures during pregnancy, childbirth and the puerperium (O00-O9A)
- mechanical complication of respirator [ventilator] (J95.850)
- poisoning and toxic effects of drugs and chemicals (T36-T65 with fifth or sixth character 1-4 or 6)
- postprocedural fever (R50.82)
- specified complications classified elsewhere, such as:
- cerebrospinal fluid leak from spinal puncture (G97.0)
- colostomy malfunction (K94.0-)
- disorders of fluid and electrolyte imbalance (E86-E87)
- functional disturbances following cardiac surgery (I97.0-I97.1)
- intraoperative and postprocedural complications of specified body systems (D78.-, E36.-, E89.-, G97.3-, G97.4, H59.3-, H59.-, H95.2-, H95.3, I97.4-, I97.5, J95.6-, J95.7, K91.6-, L76.-, M96.-, N99.-)
- ostomy complications (J95.0-, K94.-, N99.5-)
- postgastric surgery syndromes (K91.1)
- postlaminectomy syndrome NEC (M96.1)
- postmastectomy lymphedema syndrome (I97.2)
- postsurgical blind-loop syndrome (K91.2)
- ventilator associated pneumonia (J95.851)
Use additional code
- code for adverse effect, if applicable, to identify drug (T36-T50 with fifth or sixth character 5)
- code(s) to identify the specified condition resulting from the complication
- code to identify devices involved and details of circumstances (Y62-Y82)
How CDC's index refers to this code
Wording from the official alphabetic index. Much of it appears nowhere in the code description, which is why a search for the everyday phrase so often finds nothing.
- Malposition > device, implant or graft > electronic > cardiac
- Complication > cardiovascular device, graft or implant > electronic > mechanical > displacement
Codes in the same group
| Code | Description | Status |
|---|---|---|
| T82.120 | Displacement of cardiac electrode | Not billable |
| T82.121 | Displacement of cardiac pulse generator (battery) | Not billable |
| T82.128 | Displacement of other cardiac electronic device | Not billable |